If the selected element has unconnected MEP connectors, the Fabrication Bloom command will then draw a small piece of Fabrication Pipe, Duct or Containment from each connector. This includes any Equipment elements that is an instance of any Revit Families that contains MEP Connectors.


Upon execution, the Fabrication Bloom command will attempt to find an appropriate Fabrication Service Button that represents a Fabrication Straight Piece. If multiple such Fabrication Service Buttons are found, the command will use the first one that can be successfully created.


If any of the connectors on the Equipment elements does not have a matching Fabrication Service Button, or the size of the connector does not match any matching Fabrication Service Buttons, the user will be notified the specific reasons and provided guidelines to review their Fabrication Database: