The Hanger Array command places hangers for Duct, Pipe, Conduit and Cable Tray runs. It works on both Standard Revit Systems elements and Fabrication items. 


Prerequisites:

  • A valid Shared Parameter File must be appointed.
  • Hanger Array Configuration command must have been used to set up appropriate Setting-Service Associations
  • At least one compatible hanger family must exist in the BIMrx Families folder. 
    • Location of the folder: C:\ProgramData\Microdesk\BIMrx Families\<IMPERIAL or Metric>\
    • See Hanger Families for more information on loading the two simple hangers that BIMrx supplies.
    • Hanger families used in the Hanger Array command will only work with standard Revit Systems elements of duct and pipe.



In Revit:

  • Navigate to the BIMrx tab >> BIMrx Fabrication panel >> Hanger Array command. 


After user has clicked on the Hanger Array button, user will be prompted to select Duct, Pipe, Conduit and Cable Tray runs. User can also select desired runs before clicking the Hanger Array button and start this command.


The command will now place hangers according to the configurations for each Service that has been set up.


Note: If users have selected runs in Services not configured in the Hanger Array Configuration command, a dialog will display to notify the user: